Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

TLR1 Kit ELISA

Kit ELISA Humain TLR1, test Colorimetric pour la quantification de Humain TLR1.
N° du produit ABIN4973428

Aperçu rapide pour TLR1 Kit ELISA (ABIN4973428)

Antigène

Voir toutes TLR1 Kits ELISA
TLR1 (Toll-Like Receptor 1 (TLR1))

Reactivité

  • 7
  • 3
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.312 ng/mL - 20 ng/mL

Application

ELISA

Type d'échantillon

Cell Lysate, Tissue Homogenate
  • Seuil minimal de détection

    0.312 ng/mL

    Fonction

    Human Toll Like Receptor 1 (TLR1) ELISA Kit

    Analytical Method

    Quantitative

    Sensibilité

    0.19 ng/mL

    Ingrédients

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Matériel non inclus

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Indications d'application

    Optimal dilutions/concentrations should be determined by the end user.

    Commentaires

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plaque

    Pre-coated

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Toll Like Receptor 1 (TLR1) were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Toll Like Receptor 1 (TLR1) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Restrictions

    For Research Use only
  • Stock

    4 °C

    Stockage commentaire

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Date de péremption

    6 months
  • Antigène Voir toutes TLR1 Kits ELISA

    TLR1 (Toll-Like Receptor 1 (TLR1))

    Autre désignation

    Toll Like Receptor 1

    Sujet

    Ensembl: ENSG00000174125

    UniProt Entry Name: TLR1_HUMAN

    ID gène

    7096

    HGNC

    11847

    OMIM

    601194

    UniProt

    Q15399

    Pathways

    Signalisation TLR, Activation of Innate immune Response, Cellular Response to Molecule of Bacterial Origin, Toll-Like Receptors Cascades