C1R Kit ELISA

C1R Reactivité: Humain Colorimetric Sandwich ELISA 0.125-8 ng/mL Cell Culture Cells, Cerebrospinal Fluid, Milk, Plasma, Saliva, Serum, Urine
N° du produit ABIN5564590
  • Antigène Voir toutes C1R Kits ELISA
    C1R (Complement Component 1, R Subcomponent (C1R))
    Reactivité
    • 4
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.125-8 ng/mL
    Seuil minimal de détection
    0.125 ng/mL
    Application
    ELISA
    Fonction
    The AssayMax™ Human Complement C1r ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for detection of C1r in human plasma, serum, saliva, urine, milk, CSF, and cell culture samples. This assay employs a quantitative sandwich enzyme immunoassay technique that measures C1r in less than 4 hours. A polyclonal antibody specific for C1r has been pre-coated onto a 96- well microplate with removable strips. C1r in standards and samples is sandwiched by the immobilized antibody and a biotinylated polyclonal antibody specific for C1r, which is recognized by a streptavidin-peroxidase conjugate. All unbound material is washed away and a peroxidase enzyme substrate is added. The color development is stopped and the intensity of the color is measured.
    Marque
    AssayMax™
    Type d'échantillon
    Cell Culture Cells, Cerebrospinal Fluid, Milk, Plasma, Saliva, Serum, Urine
    Analytical Method
    Quantitative
    Ingrédients
    Human Complement C1r Microplate: A 96-well polystyrene microplate (12 strips of 8 wells) coated with a polyclonal antibody against human C1r. Sealing Tapes: Each kit contains 3 precut, pressure sensitive sealing tapes that can be cut to fit the format of the individual assay. Human Complement C1r Standard: Human C1r in a buffered protein base (36 ng, lyophilized). Biotinylated Human Complement C1r Antibody (100x): A 100-fold biotinylated polyclonal antibody against human C1r (80 l). EIA Diluent Concentrate (10x): A 10-fold concentrated buffered protein base (30 ml). Wash Buffer Concentrate (20x): A 20-fold concentrated buffered surfactant (30 ml, 2 bottles). Streptavidin-Peroxidase Conjugate (SP Conjugate): A 100-fold concentrate (80 l). Chromogen Substrate: A ready-to-use stabilized peroxidase chromogen substrate tetramethylbenzidine (8 ml). Stop Solution: A 0.5 N hydrochloric acid to stop the chromogen substrate reaction (12 ml).
    Matériel non inclus
    Microplate reader capable of measuring absorbance at 405 nm. Pipettes (1-20 µL, 20-200 µL, and multiple channel). Deionized or distilled reagent grade water Incubator (37 °C)
    Featured
    Discover our best selling C1R Kit ELISA
    Top Product
    Discover our top product C1R Kit ELISA
  • Durée du test
    4 h
    Plaque
    Pre-coated
    Protocole
    • Step 1. Add 50 μL of Standard or Sample per well. Incubate 2 hours.
    • Step 2. Wash, then add 50 μL of Biotinylated Antibody per well. Incubate 1 hour.
    • Step 3. Wash, then add 50 μL of SP Conjugate per well. Incubate 30 minutes.
    • Step 4. Wash, then add 50 μL of Chromogen Substrate per well. Incubate 7 minutes.
    • Step 5. Add 50 μL of Stop Solution per well. Read at 450 nm immediately.
    Préparation des réactifs

    Freshly dilute all reagents and bring all reagents to room temperature before use. EIA Diluent Concentrate (10x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the EIA Diluent Concentrate 1:10 with reagent grade water. Store for up to 30 days at 2-8 °C.

    Prélèvement de l'échantillon
    Plasma: Collect plasma using one-tenth volume of 0.1 M sodium citrate as an anticoagulant. Centrifuge samples at 3000 x g for 10 minutes. Dilute samples 1:40000 into EIA Diluent and assay. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles (EDTA or Heparin can also be used as an anticoagulant). Serum: Samples should be collected into a serum separator tube. After clot formation, centrifuge samples at 3000 x g for 10 minutes. Dilute samples 1:40000 into EIA Diluent and assay. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze- thaw cycles. Cell Culture Supernatants: Centrifuge cell culture media at 3000 x g for 10 minutes to remove debris. Collect supernatants and assay. Store the remaining samples at -20 °C or below. Avoid repeated freeze-thaw cycles. Urine: Collect urine using sample tube. Centrifuge samples at 800 x g for 10 minutes and assay. Store samples at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles. Milk: Collect milk using sample tube. Centrifuge samples at 800 x g for 10 minutes. Dilute samples 1:2000 into EIA Diluent and assay. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles. Saliva: Collect saliva using sample tube. Centrifuge samples at 800 x g for 10 minutes. Dilute samples 1:2 into EIA Diluent or within the range of 1x to 10x, and assay. The undiluted samples can be stored at -20 °C or below for up to 3 months. Avoid repeated freeze-thaw cycles. CSF: Collect cerebrospinal fluid (CSF) using sample pot. Centrifuge samples at 3000 x g for 10 minutes. Dilute samples 1:40 into EIA Diluent and assay. The undiluted samples can be stored at -80 °C for up to 3 months. Avoid repeated freeze-thaw cycles. Refer to Sample Dilution Guidelines below for further instruction. 4 Guidelines for Dilutions of 1:100 or Greater (for reference only, please follow the insert for specific dilution suggested) 1:100 1:10000 A) 4 μL sample: 396 μL buffer(100x) = 100 fold dilution Assuming the needed volume is less than or equal to 400 μL. A) 4 μL sample : 396 μL buffer (100x) B) 4 μL of A : 396 μL buffer (100x) = 10000 fold dilution Assuming the needed volume is less than or equal to 400 μL. 1:1000 1:100000 A) 4 μL sample : 396 μL buffer (100x) B) 24 μL of A : 216 μL buffer (10x) = 1000 fold dilution Assuming the needed volume is less than or equal to 240 μL. A) 4 μL sample : 396 μL buffer (100x) B) 4 μL of A : 396 μL buffer (100x) C) 24 μL of B : 216 μL buffer (10x) = 100000 fold dilution Assuming the needed volume is less than or equal to 240 μL.
    Procédure de l'essai

    Prepare all reagents, standard solutions, and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature (20-25 °C). Remove excess microplate strips from the plate frame and return them immediately to the foil pouch with desiccants inside. Reseal the pouch securely to minimize exposure to water vapor and store in a vacuum desiccator. Add 50 l of Human Complement C1r Standard or sample per well. Cover wells with a sealing tape and incubate for 2 hours. Start the timer after the last addition. Wash five times with 200 l of Wash Buffer manually. Invert the plate each time and decant the contents, hit 4-5 times on absorbent material to completely remove the liquid. If using a machine, wash six times with 300 l of Wash Buffer and then invert the plate, decanting the contents, hit 4-5 times on absorbent material to completely remove the liquid. Add 50 l of Biotinylated Human Complement C1r Antibody to each well and incubate for 1 hour. Wash the microplate as described above. Add 50 l of Streptavidin-Peroxidase Conjugate per well and incubate for 30 minutes. Turn on the microplate reader and set up the program in advance. Wash the microplate as described above. Add 50 l of Chromogen Substrate per well and incubate for 7 minutes or till the optimal blue color density develops. Gently tap the plate to ensure thorough mixing and break the bubbles in the well with pipette tip. Add 50 l of Stop Solution to each well. The color will change from blue to yellow. Read the absorbance on a microplate reader at a wavelength of 450 nm immediately. If wavelength correction is available, subtract readings at 570 nm from those at 450 nm to correct optical imperfections. Otherwise, read the plate at 450 nm only. Please note that some 6 unstable black particles may be generated at high concentration points after stopping the reaction for about 10 minutes, which will reduce the readings.

    Calcul des résultats
    • Calculate the mean value of the duplicate or triplicate readings for each standard and sample.
    • To generate a standard curve, plot the graph using the standard concentrations on the x-axis and the corresponding mean 450 nm absorbance (OD) on the y-axis. The best-fit line can be determined by regression analysis using log-log or four-parameter logistic curve-fit.
    • Determine the unknown sample concentration from the standard curve and multiply the value by the dilution factor.
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    This product is for Research Use Only and is Not For Use In Diagnostic Procedures. Prepare all reagents (working diluent buffer, wash buffer, standard, biotinylated antibody, and SP conjugate) as instructed, prior to running the assay. 2 Prepare all samples prior to running the assay. The dilution factors for the samples are suggested in this insert. However, the user should determine the optimal dilution factor. Spin down the SP conjugate vial and the biotinylated antibody vial before opening and using contents. The Stop Solution is an acidic solution. The kit should not be used beyond the expiration date.
    Stock
    4 °C,-20 °C
    Stockage commentaire
    Upon arrival, immediately store components of the kit at recommended temperatures up to the expiration date. Store SP Conjugate and Biotinylated Antibody at -20°C. Store Microplate, Diluent Concentrate (10x), Wash Buffer, Stop Solution, and Chromogen Substrate at 2-8°C. Unused microplate wells may be returned to the foil pouch with the desiccant packs and resealed. May be stored for up to 30 days in a vacuum desiccator. Diluent (1x) may be stored for up to 30 days at 2-8°C. Store Standard at 2-8°C before reconstituting with Diluent and at -20°C after reconstituting with Diluent. 3
  • Antigène Voir toutes C1R Kits ELISA
    C1R (Complement Component 1, R Subcomponent (C1R))
    Autre désignation
    Complement C1r (C1R Produits)
    Synonymes
    C1R Kit ELISA, MGC84776 Kit ELISA, MGC127774 Kit ELISA, c1rl Kit ELISA, complement C1r Kit ELISA, complement component 1, r subcomponent L homeolog Kit ELISA, complement component 1, r subcomponent Kit ELISA, C1R Kit ELISA, C1r Kit ELISA, c1r.L Kit ELISA, c1r Kit ELISA
    Sujet
    Complement component C1r is a zymogen of a serine protease that combines with C1q and C1s to form C1, the first component of the classical complement pathway. C1r is a dimer of identical chains and a key mediator of innate immunity. Each precursor contains a 17-amino acid leader peptide, followed by a mature 688-amino acid protein (1). Upon C1q binding to the surface of pathogens, the activated C1r is cleavage into two chains, A and B, connected by disulfide bonds. The non-catalytic amino-terminal C1r A chain (heavy) has 446 amino acids residues (Mr 51 kDa) and contains a growth factor domain and two internal repeats. The catalytic C1r B chain (light) contains 242 amino acids (Mr 27 kDa) and is homologous to the trypsin family of serine proteases. The activated C1r is able to activate C1s which in turn activates C2 and C4, leading to the formation of the membrane attack complex and the elimination of the target (2, 3).
    ID gène
    715
    UniProt
    P00736
    Pathways
    Système du Complément
Vous êtes ici:
Support technique