Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

RAGE Kit CLIA

Ce kit ELISA Chemiluminescent est destiné à la mesure quantitative de Souris RAGE.
N° du produit ABIN5651508
1.291,85 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour RAGE Kit CLIA (ABIN5651508)

Antigène

Voir toutes RAGE (AGER) Kits CLIA
RAGE (AGER) (Advanced Glycosylation End Product-Specific Receptor (AGER))

Reactivité

  • 24
  • 23
  • 17
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
Souris

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

13.7 pg/mL - 10000 pg/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    13.7 pg/mL

    Fonction

    Mouse Receptor For Advanced Glycation Endproducts (RAGE) CLIA Kit for detecting RAGE in serum, plasma, tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Advanced Glycosylation End Product Specific Receptor (AGER). No significant cross-reactivity or interference between Advanced Glycosylation End Product Specific Receptor (AGER) and analogues was observed.

    Sensibilité

    4.4 pg/mL

    Ingrédients

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Matériel non inclus

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Advanced Glycosylation End Product Specific Receptor (AGER). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Advanced Glycosylation End Product Specific Receptor (AGER). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Advanced Glycosylation End Product Specific Receptor (AGER) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Advanced Glycosylation End Product Specific Receptor (AGER) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Advanced Glycosylation End Product Specific Receptor (AGER) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    12 months
  • Antigène Voir toutes RAGE (AGER) Kits CLIA

    RAGE (AGER) (Advanced Glycosylation End Product-Specific Receptor (AGER))

    Autre désignation

    Receptor For Advanced Glycation Endproducts

    Sujet

    Gene Aliases: AGER, Receptor For Advanced Glycation Endproducts

    ID gène

    11596

    UniProt

    Q62151

    Pathways

    Carbohydrate Homeostasis, Toll-Like Receptors Cascades, Smooth Muscle Cell Migration, S100 Proteins
Vous êtes ici:
Chat with us!