Annexin A2 Kit CLIA
Aperçu rapide pour Annexin A2 Kit CLIA (ABIN5651832)
Antigène
Voir toutes Annexin A2 (ANXA2) Kits CLIAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 54.9 pg/mL
-
Fonction
- Human Annexin A2 (ANXA2) CLIA Kit for detecting ANXA2 in serum, plasma
-
Analytical Method
- Quantitative
-
Specificité
- This assay has high sensitivity and excellent specificity for detection of Annexin A2 (ANXA2). No significant cross-reactivity or interference between Annexin A2 (ANXA2) and analogues was observed.
-
Sensibilité
- 21.7 pg/mL
-
Ingrédients
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
Matériel non inclus
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
Indications d'application
- Optimal working dilution should be determined by the investigator.
-
Commentaires
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
Volume d'échantillon
- 100 μL
-
Durée du test
- 3 h
-
Plaque
- Pre-coated
-
Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to Annexin A2 (ANXA2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Annexin A2 (ANXA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Annexin A2 (ANXA2) level in the sample or standard.,
-
Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Annexin A2 (ANXA2) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Annexin A2 (ANXA2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Stock
- 4 °C,-20 °C
-
Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Date de péremption
- 12 months
-
-
- Annexin A2 (ANXA2)
-
Autre désignation
- Annexin A2
-
Sujet
- Gene Aliases: ANX-A2, ANX2L4, CAL1H, LIP2, LPC2, LPC2D, P36, PAP-IV, Protein I, Chromobindin-8, Calpactin-1 heavy chain, Lipocortin II, Placental anticoagulant protein IV
-
ID gène
- 302
-
UniProt
- P07355
-
Pathways
- S100 Proteins
Antigène Voir toutes Annexin A2 (ANXA2) Kits CLIA
-