Ce kit ELISA Chemiluminescent est conçu pour la mesure quantitative de Humain PDIA2.
N° du produit ABIN5658198

Aperçu rapide pour PDIA2 Kit CLIA (ABIN5658198)

Antigène

Voir toutes PDIA2 Kits CLIA
PDIA2 (Protein Disulfide Isomerase Family A, Member 2 (PDIA2))

Reactivité

  • 3
  • 1
Humain

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

156.25 pg/mL - 10000 pg/mL

Application

ELISA

Type d'échantillon

Tissue Homogenate
  • Seuil minimal de détection

    156.25 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Protein Disulfide Isomerase A2 (PDIA2). No significant cross-reactivity or interference between Protein Disulfide Isomerase A2 (PDIA2) and analogues was observed.

    Sensibilité

    5.94 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 - 3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Protein Disulfide Isomerase A2 (PDIA2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Protein Disulfide Isomerase A2 (PDIA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Protein Disulfide Isomerase A2 (PDIA2) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Protein Disulfide Isomerase A2 (PDIA2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Protein Disulfide Isomerase A2 (PDIA2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes PDIA2 Kits CLIA

    PDIA2 (Protein Disulfide Isomerase Family A, Member 2 (PDIA2))

    Autre désignation

    Protein Disulfide Isomerase A2

    Sujet

    Gene Name: Protein Disulfide Isomerase A2

    Gene Aliases: PDI-A2, PDA2, PDI, PDIR, PDIP, Protein Disulfide Isomerase,Pancreatic, Protein Disulfide Isomerase-Associated 2, Pancreas-specific protein disulfide isomerase

    ID gène

    64714

    UniProt

    Q13087

    Pathways

    Maintenance of Protein Location, Cell RedoxHomeostasis, Unfolded Protein Response