IFI16 Kit ELISA
Aperçu rapide pour IFI16 Kit ELISA (ABIN7671643)
Antigène
Voir toutes IFI16 Kits ELISAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
Classe de qualité
-
-
Seuil minimal de détection
- 0.156 ng/mL
-
Fonction
- Human IFI16 (Gamma-interferon-inducible protein 16) QuickTest ELISA Kit
-
Analytical Method
- Quantitative
-
Specificité
- Specifically binds with IFI16 , no obvious cross reaction with other analogues.
-
Sensibilité
- 0.094 ng/mL
-
Ingrédients
-
- ELISA Microplate(Dismountable)
- Lyophilized Standard
- Cap/Det Ab (Ready to use
- blue)
- TMB Substrate
- Sample Dilution Buffer
- Stop Solution
- Plate Sealer
- Product Description
-
Matériel non inclus
-
- Microplate reader (wavelength: 450nm)
- 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5 mL pipettor
- Precision single (0.5-10μL
- 5-50μL
- 20-200μL
- 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
-
-
-
-
Indications d'application
- Optimal working dilution should be determined by the investigator.
-
Commentaires
-
Sandwich ELISA, Double Antibody
-
Volume d'échantillon
- 50 μL
-
Durée du test
- 2 h
-
Plaque
- Pre-coated
-
Protocole
- Step 1: Take out the required plate wells, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into individual well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure thorough mixing then static incubate for 60 minutes at 37 °C. Washing: Wash the plate twice without immersion. Step 2: Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and static incubate for 30 minutes at 37 °C. Washing: Wash the plate five times without immersion. Step 3: Add 90 µL TMB substrate solution, seal the plate and static incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 4: Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Procédure de l'essai
-
- Take out the required strips, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into relevant well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure complete mixing then statically incubate for 60 minutes at 37 °C.
- Wash the plate twice without immersion.
- Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and statically incubate for 30 minutes at 37 °C.
- Wash the plate five times without immersion.
- Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C (Accurate TMB visualization control is required.).
- Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- Avoid direct light exposure to antibody solutions
-
Stock
- 4 °C
-
Stockage commentaire
- Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant
-
Date de péremption
- 12 months
-
-
- IFI16 (Interferon, gamma-Inducible Protein 16 (IFI16))
-
Autre désignation
- IFI16
-
Sujet
- Gamma-interferon-inducible protein 16, Ifi-16, Interferon-inducible myeloid differentiation transcriptional activator, IFI16, IFNGIP1
-
UniProt
- Q16666
-
Pathways
- Activation of Innate immune Response, Positive Regulation of Endopeptidase Activity, Autophagy, Inflammasome
Antigène Voir toutes IFI16 Kits ELISA
-