Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

IL-4 Kit ELISA

Ce kit ELISA Colorimetric est destiné à la mesure quantitative de Humain IL-4.
N° du produit ABIN8056653
666,11 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 11 à 15 jours ouvrables

Aperçu rapide pour IL-4 Kit ELISA (ABIN8056653)

Antigène

Voir toutes IL-4 (IL4) Kits ELISA
IL-4 (IL4) (Interleukin 4 (IL4))

Reactivité

  • 34
  • 28
  • 27
  • 11
  • 11
  • 10
  • 10
  • 9
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

7.8 pg/mL - 500 pg/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate

Classe de qualité

High Sensitivity
  • Seuil minimal de détection

    7.8 pg/mL

    Fonction

    High Sensitive ELISA Kit for Interleukin 4 (IL4)

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of High Sensitive Interleukin 4 (IL4).
    No significant cross-reactivity or interference between High Sensitive Interleukin 4 (IL4) and analogues was observed.

    Sensibilité

    < 3.0 pg/mL

    Ingrédients

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    Matériel non inclus

    • Microplate reader with 450 ± 10nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    8. Add 50µL Stop Solution. Read at 450nm immediately.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Interleukin 4 (IL4) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Interleukin 4 (IL4) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Date de péremption

    6 months
  • Antigène Voir toutes IL-4 (IL4) Kits ELISA

    IL-4 (IL4) (Interleukin 4 (IL4))

    Autre désignation

    Interleukin 4

    Sujet

    BSF1, BCGF1 ,B Cell Stimulatory Factor 1, Lymphocyte stimulatory factor 1, B Cell Growth Factor, Binetrakin, Pitrakinra

    UniProt

    P05112

    Pathways

    Signalistation JAK/STAT, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Proton Transport, Activated T Cell Proliferation
Vous êtes ici:
Chat with us!