SNCA Kit ELISA
Aperçu rapide pour SNCA Kit ELISA (ABIN5659072)
Antigène
Voir toutes SNCA Kits ELISAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 3.12 ng/mL
-
Analytical Method
- Quantitative
-
Specificité
- This assay has high sensitivity and excellent specificity for detection of Synuclein Alpha (SNCa). No significant cross-reactivity or interference between Synuclein Alpha (SNCa) and analogues was observed.
-
Sensibilité
- 1.17 ng/mL
-
-
-
-
Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
Durée du test
- 2 - 3 h
-
Plaque
- Pre-coated
-
Protocole
- This assay employs the competitive inhibition enzyme immunoassay technique. An antibody specific to Synuclein Alpha (SNCa) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between Horseradish Peroxidase (HRP) labeled Synuclein Alpha (SNCa) and unlabeled Synuclein Alpha (SNCa) (Standards or samples) with the pre-coated antibody specific to Synuclein Alpha (SNCa). After incubation the unbound conjugate is washed off. The amount of bound HRP conjugate is reverse proportional to the concentration of Synuclein Alpha (SNCa) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Synuclein Alpha (SNCa) in the sample.
-
Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Synuclein Alpha (SNCa) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Synuclein Alpha (SNCa) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Stock
- 4 °C,-20 °C
-
Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Date de péremption
- 4-8 months
-
-
- SNCA (Synuclein, alpha (SNCA))
-
Autre désignation
- Synuclein Alpha
-
Sujet
-
Gene Name: Synuclein Alpha
Gene Aliases: SNC-A, aSYN, PD1, PARK1, PARK4, NACP, Non-A Beta Component Of Alzheimer's Disease Amyloid Precursor Protein, Non-A4 component of amyloid precursor
-
Pathways
- Synaptic Membrane, Regulation of G-Protein Coupled Receptor Protein Signaling, Positive Regulation of Endopeptidase Activity, Regulation of Carbohydrate Metabolic Process, Platelet-derived growth Factor Receptor Signaling, Negative Regulation of Transporter Activity, Regulation of long-term Neuronal Synaptic Plasticity
Antigène Voir toutes SNCA Kits ELISA
-