Stanniocalcin 2 Kit ELISA
Aperçu rapide pour Stanniocalcin 2 Kit ELISA (ABIN6730291)
Antigène
Voir toutes Stanniocalcin 2 (STC2) Kits ELISAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 0.15 ng/mL
-
Fonction
- Mouse STC-2 ELISA Kit for Serum, Plasma, and Cell Culture Supernatants.
-
Analytical Method
- Quantitative
-
Specificité
- This ELISA kit shows no cross-reactivity with the following cytokines tested: Mouse Ret, RGM-B, RGM-C, ROBO3, SEMA3C, SEMA3F, SEMA4C, SEMA4F, SEMA4G, SEMA6C, Siglec-3, Siglec-E, SIGNR1, Slit2, SMOC-1, SorCS2, SP-D, SR-AI, Syndecan-1, Syndecan-3, TFPI-2, TGF-beta RI, TGF-beta RII, TGM2, TIGIT, TIM-3, TLR2, TNFRH3, Tpo R, TRAIL R2, TREM-2, TrkC, TROP-2, Trypsin 3, Tryptase-5, TSLP R, uPAR, VE-Cadherin, Wnt-2b.
-
Attributs du produit
-
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
-
Ingrédients
-
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
-
Matériel non inclus
-
- Distilled or deionized water
- Precision pipettes to deliver 2 μL to 1 μL volumes
- Adjustable 1-25 μL pipettes for reagent preparation
- 100 μL and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
-
-
-
-
Indications d'application
- Suggested Plasma Dilution: 2 fold
-
Plaque
- Pre-coated
-
Protocole
-
- Prepare all reagents, samples and standards as instructed in the manual.
- Add 100 μL of standard or sample to each well.
- Incubate 2.5 h at RT or O/N at 4 °C.
- Add 100 μL of prepared biotin antibody to each well.
- Incubate 1 h at RT.
- Add 100 μL of prepared Streptavidin solution to each well.
- Incubate 45 min at RT.
- Add 100 μL of TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 μL of Stop Solution to each well.
- Read at 450 nm immediately.
-
Restrictions
- For Research Use only
-
-
-
Stock
- -20 °C
-
Stockage commentaire
- The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
-
Date de péremption
- 6 months
-
-
- Stanniocalcin 2 (STC2)
-
Autre désignation
- STC-2
-
Sujet
-
Gene Symbols: Stc2
Protein Name (Synonyms): Stanniocalcin-2 (STC-2)
-
ID gène
- 20856
-
UniProt
- O88452
-
Pathways
- Hormone Activity, ER-Nucleus Signaling, SARS-CoV-2 Protein Interactome
Antigène Voir toutes Stanniocalcin 2 (STC2) Kits ELISA
-