Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

ROR1 Kit CLIA

Kit ELISA ROR1 Humain, Chemiluminescent test pour la quantification de Humain ROR1.
N° du produit ABIN8056088
1.026,67 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 11 à 15 jours ouvrables

Aperçu rapide pour ROR1 Kit CLIA (ABIN8056088)

Antigène

Voir toutes ROR1 Kits CLIA
ROR1 (Receptor Tyrosine Kinase-Like Orphan Receptor 1 (ROR1))

Reactivité

  • 6
  • 2
Humain

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

68.6 pg/mL - 50000 pg/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    68.6 pg/mL

    Fonction

    CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1).
    No significant cross-reactivity or interference between Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) and analogues was observed.

    Sensibilité

    < 23.1 pg/mL

    Ingrédients

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • Substrate A
    • Substrate B
    • Wash Buffer (30X)
    • Instruction manual

    Matériel non inclus

    • Luminometer capable of reading 96-well microplates with the following parameters: lag time 30.0secs; read time 1.0 sec/well
    • Single or multi-channel pipettes with high precision and disposable tips.
    • Microcentrifuge Tubes.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microplate.
    • Container for Wash Solution.
    • 0.01mol/L (or 1×) Phosphate Buffered Saline(PBS), pH7.0-7.2
  • Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
    8. Read RLU value immediately.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    Date de péremption

    6 months
  • Antigène Voir toutes ROR1 Kits CLIA

    ROR1 (Receptor Tyrosine Kinase-Like Orphan Receptor 1 (ROR1))

    Autre désignation

    Receptor Tyrosine Kinase Like Orphan Receptor 1

    Sujet

    NTRKR1, Tyrosine-protein kinase transmembrane receptor ROR1, Neurotrophic tyrosine kinase, receptor-related 1

    UniProt

    Q01973

    Pathways

    Signalisation RTK, Signalisation WNT, Nuclear Receptor Transcription Pathway, Steroid Hormone Mediated Signaling Pathway, Regulation of Lipid Metabolism by PPARalpha
Vous êtes ici:
Chat with us!