Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

ESM1 Kit ELISA

ESM1 Reactivité: Rat Colorimetric Sandwich ELISA 78.13 pg/mL - 5000 pg/mL Plasma, Serum
N° du produit ABIN4993433
  • Antigène Voir toutes ESM1 Kits ELISA
    ESM1 (Endothelial Cell-Specific Molecule 1 (ESM1))
    Reactivité
    • 5
    • 5
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    78.13 pg/mL - 5000 pg/mL
    Seuil minimal de détection
    78.13 pg/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of ESM1 in Rat serum, plasma and other biological fluids
    Type d'échantillon
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    This kit recognizes natural and recombinantRatESM1. No significant cross-reactivity or interference between RatESM1 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between RatESM1 and all the analogues.
    Sensibilité
    46.88 pg/mL
    Ingrédients
    Micro ELISA Plate
    Reference Standard
    Concentrated Biotinylated Detection Ab
    Concentrated HRP Conjugate
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solutio
    Plate Sealer
    Product Description
    Certificate of Analysis
    Matériel non inclus
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Discover our best selling ESM1 Kit ELISA
    Top Product
    Discover our top product ESM1 Kit ELISA
  • Commentaires

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Volume d'échantillon
    100 µL
    Plaque
    Pre-coated
    Protocole
    This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to ESM1. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for ESM1and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain ESM1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of ESM1.You can calculate the concentration of ESM1in the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Antigène Voir toutes ESM1 Kits ELISA
    ESM1 (Endothelial Cell-Specific Molecule 1 (ESM1))
    Autre désignation
    Endothelial Cell Specific Molecule 1 (ESM1) (ESM1 Produits)
    Synonymes
    ESM1 Kit ELISA, zgc:153027 Kit ELISA, 0610042H23Rik Kit ELISA, AV004503 Kit ELISA, ESM-1 Kit ELISA, Pg25 Kit ELISA, endocan Kit ELISA, endothelial cell specific molecule 1 Kit ELISA, endothelial cell-specific molecule 1 Kit ELISA, ESM1 Kit ELISA, esm1 Kit ELISA, Esm1 Kit ELISA
    Pathways
    Growth Factor Binding
Vous êtes ici:
Support technique