Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

SLC40A1 Kit ELISA

SLC40A1 Reactivité: Humain Colorimetric Sandwich ELISA 0.31 ng/mL - 20 ng/mL Plasma, Serum
N° du produit ABIN5519115
  • Antigène Voir toutes SLC40A1 Kits ELISA
    SLC40A1 (Solute Carrier Family 40 (Iron-Regulated Transporter), Member 1 (SLC40A1))
    Reactivité
    • 3
    • 3
    • 3
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.31 ng/mL - 20 ng/mL
    Seuil minimal de détection
    0.31 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.
    Type d'échantillon
    Plasma, Serum
    Analytical Method
    Quantitative
    Sensibilité
    0.19 ng/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Reference Standard & Sample Diluent
    • Biotinylated Detection Antibody (100 x concentrate)
    • HRP Conjugate (100 x concentrate)
    • Biotinylated Detection Antibody Diluent
    • HRP Conjugate Diluent
    • Substrate Reagent
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling SLC40A1 Kit ELISA
    Top Product
    Discover our top product SLC40A1 Kit ELISA
  • Volume d'échantillon
    100 µL
    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Protocole
    1. Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
    2. Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
    3. Aspirate and wash 3 times.
    4. Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
    5. Aspirate and wash 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450 nm immediately.
    8. Calculation of results.
    Préparation des réactifs
    1. Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
    2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
    3. Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 20 ng/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 20, 10, 5, 2.5, 1.25, 0.63, 0.31, 0 ng/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 20 ng/mL working solution to the first tube and mix up to produce a 10 ng/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
    4. Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
    5. Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.
    Restrictions
    For Research Use only
  • Stock
    4 °C/-20 °C
    Stockage commentaire
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Antigène Voir toutes SLC40A1 Kits ELISA
    SLC40A1 (Solute Carrier Family 40 (Iron-Regulated Transporter), Member 1 (SLC40A1))
    Autre désignation
    FPN(Ferroportin) (SLC40A1 Produits)
    Synonymes
    FPN1 Kit ELISA, HFE4 Kit ELISA, IREG1 Kit ELISA, MST079 Kit ELISA, MTP1 Kit ELISA, SLC11A3 Kit ELISA, slc39a1 Kit ELISA, weh Kit ELISA, slc40a1 Kit ELISA, MGC82700 Kit ELISA, SLC40A1 Kit ELISA, Fpn1 Kit ELISA, Slc11a3 Kit ELISA, Slc39a1 Kit ELISA, Dusg Kit ELISA, MTP Kit ELISA, Ol5 Kit ELISA, Pcm Kit ELISA, ARABIDOPSIS THALIANA IRON-REGULATED PROTEIN 1 Kit ELISA, ATIREG1 Kit ELISA, FERROPORTIN 1 Kit ELISA, T19C21.5 Kit ELISA, T19C21_5 Kit ELISA, iron regulated 1 Kit ELISA, ARABIDOPSIS IRON-REGULATED TRANSPORTER 1 Kit ELISA, ATIRT1 Kit ELISA, T16H5.50 Kit ELISA, T16H5_50 Kit ELISA, iron-regulated transporter 1 Kit ELISA, solute carrier family 40 member 1 Kit ELISA, solute carrier family 40 (iron-regulated transporter), member 1 Kit ELISA, solute carrier family 40 (iron-regulated transporter), member 1 S homeolog Kit ELISA, iron regulated 1 Kit ELISA, iron-regulated transporter 1 Kit ELISA, SLC40A1 Kit ELISA, slc40a1 Kit ELISA, slc40a1.S Kit ELISA, Slc40a1 Kit ELISA, IREG1 Kit ELISA, IRT1 Kit ELISA
    Pathways
    Transition Metal Ion Homeostasis
Support technique