XIAP Kit CLIA
Aperçu rapide pour XIAP Kit CLIA (ABIN5655358)
Antigène
Voir toutes XIAP Kits CLIAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 156.25 pg/mL
-
Analytical Method
- Quantitative
-
Specificité
- This assay has high sensitivity and excellent specificity for detection of Inhibitor Of Apoptosis Protein, X-Linked (XIAP). No significant cross-reactivity or interference between Inhibitor Of Apoptosis Protein, X-Linked (XIAP) and analogues was observed.
-
Sensibilité
- 4.81 pg/mL
-
-
-
-
Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
Durée du test
- 2 - 3 h
-
Plaque
- Pre-coated
-
Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to Inhibitor Of Apoptosis Protein, X-Linked (XIAP). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Inhibitor Of Apoptosis Protein, X-Linked (XIAP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Inhibitor Of Apoptosis Protein, X-Linked (XIAP) level in the sample or standard.,
-
Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibitor Of Apoptosis Protein, X-Linked (XIAP) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibitor Of Apoptosis Protein, X-Linked (XIAP) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Stock
- 4 °C,-20 °C
-
Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Date de péremption
- 4-8 months
-
-
- XIAP (X-Linked Inhibitor of Apoptosis (XIAP))
-
Autre désignation
- Inhibitor Of Apoptosis Protein, X-Linked
-
Sujet
-
Gene Name: Inhibitor Of Apoptosis Protein, X-Linked
Gene Aliases: BIRC4, API3, ILP1, MIHA, XLP2, Baculoviral IAP Repeat-Containing 4, E3 ubiquitin-protein ligase XIAP, IAP-like, Inhibitor of apoptosis protein 3, X-linked inhibitor of apoptosis protein
-
ID gène
- 331
-
UniProt
- P98170
-
Pathways
- Apoptose, Caspase Cascade in Apoptosis, Transition Metal Ion Homeostasis
Antigène Voir toutes XIAP Kits CLIA
-