Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

IL12 Kit ELISA

Ce kit ELISA Colorimetric est destiné à la mesure quantitative de Singe IL12.
N° du produit ABIN7671669
652,31 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 11 à 15 jours ouvrables

Aperçu rapide pour IL12 Kit ELISA (ABIN7671669)

Antigène

Voir toutes IL12 Kits ELISA
IL12 (Interleukin 12 (IL12))

Reactivité

  • 43
  • 27
  • 13
  • 8
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 1
Singe

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

15.625 pg/mL - 1000 pg/mL

Application

ELISA

Type d'échantillon

Biological Fluids, Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Lysate

Classe de qualité

Quick
  • Seuil minimal de détection

    15.625 pg/mL

    Fonction

    Monkey IL-12 (Interleukin 12) QuickTest ELISA Kit

    Analytical Method

    Quantitative

    Specificité

    Specifically binds with IL-12 , no obvious cross reaction with other analogues.

    Sensibilité

    9.375 pg/mL

    Ingrédients

    • ELISA Microplate(Dismountable)
    • Lyophilized Standard
    • Cap/Det Ab (Ready to use
    • blue)
    • TMB Substrate
    • Sample Dilution Buffer
    • Stop Solution
    • Plate Sealer
    • Product Description

    Matériel non inclus

    • Microplate reader (wavelength: 450nm)
    • 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
    • Automated plate washer or multi-channel pipette/5 mL pipettor
    • Precision single (0.5-10μL
    • 5-50μL
    • 20-200μL
    • 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
    • Sterile tubes and Eppendorf tubes with disposable tips
    • Absorbent paper and loading slot
    • Deionized or distilled water
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    Sandwich ELISA, Double Antibody

    Volume d'échantillon

    50 μL

    Durée du test

    2 h

    Plaque

    Pre-coated

    Protocole

    Step 1: Take out the required plate wells, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into individual well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure thorough mixing then static incubate for 60 minutes at 37 °C. Washing: Wash the plate twice without immersion. Step 2: Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and static incubate for 30 minutes at 37 °C. Washing: Wash the plate five times without immersion. Step 3: Add 90 µL TMB substrate solution, seal the plate and static incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 4: Add 50 µL stop solution. Read at 450nm immediately and calculate.

    Procédure de l'essai

    1. Take out the required strips, add 50 µL Cap/Det Ab into each well, then add 50 µL Standard or Sample into relevant well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure complete mixing then statically incubate for 60 minutes at 37 °C.
    2. Wash the plate twice without immersion.
    3. Add 100 µL HRP-Streptavidin (orange) into each well, seal the plate and statically incubate for 30 minutes at 37 °C.
    4. Wash the plate five times without immersion.
    5. Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C (Accurate TMB visualization control is required.).
    6. Add 50 µL stop solution. Read at 450nm immediately and calculate.

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Avoid direct light exposure to antibody solutions

    Stock

    4 °C

    Stockage commentaire

    Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant

    Date de péremption

    12 months
  • Antigène Voir toutes IL12 Kits ELISA

    IL12 (Interleukin 12 (IL12))

    Autre désignation

    IL-12

    Sujet

    IL-12, Interleukin-12 subunit alpha, IL-12A, Cytotoxic lymphocyte maturation factor 35 kDa subunit, CLMF p35, IL-12 subunit p35, NK cell stimulatory factor chain 1, NKSF1, IL12A, NKSF1, Interleukin-12 subunit beta, IL-12B, Cytotoxic lymphocyte maturation factor 40 kDa subunit, CLMF p40, IL-12 subunit p40, NK cell stimulatory factor chain 2, NKSF2, IL12B, NKSF2

    Pathways

    Signalistation JAK/STAT, Signalisation TLR, Cellular Response to Molecule of Bacterial Origin, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Activated T Cell Proliferation, Cancer Immune Checkpoints, Inflammasome
Vous êtes ici:
Chat with us!