KARS Kit ELISA
-
- Antigène Voir toutes KARS Kits ELISA
- KARS (Lysyl-tRNA Synthetase (KARS))
-
Reactivité
- Souris
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 62.5-4000 pg/mL
- Seuil minimal de détection
- 62.5 pg/mL
- Application
- ELISA
- Fonction
- The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of KARS in Mouse serum, plasma and other biological fluids
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This kit recognizes natural and recombinantMouseKARS. No significant cross-reactivity or interference between MouseKARS and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between MouseKARS and all the analogues.
- Sensibilité
- 37.5 pg/mL
- Ingrédients
-
Micro ELISA Plate
Reference Standard
Concentrated Biotinylated Detection Ab
Concentrated HRP Conjugate
Reference Standard & Sample Diluent
Biotinylated Detection Ab Diluent
HRP Conjugate Diluent
Concentrated Wash Buffer (25×)
Substrate Reagent
Stop Solutio
Plate Sealer
Product Description
Certificate of Analysis - Matériel non inclus
-
Microplate reader with 450nm wavelength filter
High-precision transferpettor, EP tubes and disposable pipette tips
37℃ Incubator
Deionized or distilled water
Absorbent paper
Loading slot for Wash Buffer - Featured
- Discover our best selling KARS Kit ELISA
- Top Product
- Discover our top product KARS Kit ELISA
-
-
- Commentaires
-
Information on standard material:
The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).
Information on reagents:
Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.
Information on antibodies:
The provided antibodies and their host vary in different kits. All antibodies are affinity purified
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration. - Volume d'échantillon
- 100 µL
- Plaque
- Pre-coated
- Protocole
- This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to KARS. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for KARSand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain KARS, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of KARS.You can calculate the concentration of KARSin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
- Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
- Stock
- 4 °C/-20 °C
- Stockage commentaire
- The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
-
- Antigène Voir toutes KARS Kits ELISA
- KARS (Lysyl-tRNA Synthetase (KARS))
- Autre désignation
- Lysyl tRNA Synthetase (KARS) (KARS Produits)
- Synonymes
- CG12141 Kit ELISA, Dmel\\CG12141 Kit ELISA, KRS Kit ELISA, LysRS Kit ELISA, cb530 Kit ELISA, wu:fa16h02 Kit ELISA, zgc:92483 Kit ELISA, kars Kit ELISA, MGC53345 Kit ELISA, kars2 Kit ELISA, krs Kit ELISA, krs-1 Kit ELISA, KARS Kit ELISA, Tb06.28P18.190 Kit ELISA, CMTRIB Kit ELISA, DFNB89 Kit ELISA, KARS1 Kit ELISA, KARS2 Kit ELISA, AA589550 Kit ELISA, AL024334 Kit ELISA, AL033315 Kit ELISA, AL033367 Kit ELISA, D8Ertd698e Kit ELISA, D8Wsu108e Kit ELISA, mKIAA0070 Kit ELISA, Lysyl-tRNA synthetase Kit ELISA, lysyl-tRNA synthetase Kit ELISA, lysyl-tRNA synthetase S homeolog Kit ELISA, lysyl-tRNA synthetase L homeolog Kit ELISA, LysRS Kit ELISA, kars Kit ELISA, kars.S Kit ELISA, kars.L Kit ELISA, Bm1_16500 Kit ELISA, lysS Kit ELISA, Taci_1118 Kit ELISA, Tpau_1737 Kit ELISA, Arch_0261 Kit ELISA, Trad_2960 Kit ELISA, Spirs_3699 Kit ELISA, KARS Kit ELISA, LOC100280510 Kit ELISA, Tb927.6.1510 Kit ELISA, Kars Kit ELISA
-