SORD Kit ELISA
-
- Antigène Voir toutes SORD Kits ELISA
- SORD (Sorbitol Dehydrogenase (SORD))
-
Reactivité
- Rat
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 1.56 ng/mL - 100 ng/mL
- Seuil minimal de détection
- 1.56 ng/mL
- Application
- ELISA
- Fonction
- The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of SDH in Rat serum, plasma and other biological fluids
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This kit recognizes natural and recombinantRatSDH. No significant cross-reactivity or interference between RatSDH and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between RatSDH and all the analogues.
- Sensibilité
- 0.94 ng/mL
- Ingrédients
-
Micro ELISA Plate
Reference Standard
Concentrated Biotinylated Detection Ab
Concentrated HRP Conjugate
Reference Standard & Sample Diluent
Biotinylated Detection Ab Diluent
HRP Conjugate Diluent
Concentrated Wash Buffer (25×)
Substrate Reagent
Stop Solutio
Plate Sealer
Product Description
Certificate of Analysis - Matériel non inclus
-
Microplate reader with 450nm wavelength filter
High-precision transferpettor, EP tubes and disposable pipette tips
37℃ Incubator
Deionized or distilled water
Absorbent paper
Loading slot for Wash Buffer - Featured
- Discover our best selling SORD Kit ELISA
- Top Product
- Discover our top product SORD Kit ELISA
-
-
- Commentaires
-
Information on standard material:
The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).
Information on reagents:
Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.
Information on antibodies:
The provided antibodies and their host vary in different kits. All antibodies are affinity purified
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration. - Volume d'échantillon
- 100 µL
- Plaque
- Pre-coated
- Protocole
- This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to SDH. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for SDHand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain SDH, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of SDH.You can calculate the concentration of SDHin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
- Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
- Stock
- 4 °C/-20 °C
- Stockage commentaire
- The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
-
- Antigène Voir toutes SORD Kits ELISA
- SORD (Sorbitol Dehydrogenase (SORD))
- Autre désignation
- Sorbitol Dehydrogenase (SDH) (SORD Produits)
- Synonymes
- SORD1 Kit ELISA, Sdh-1 Kit ELISA, Sdh1 Kit ELISA, Sodh-1 Kit ELISA, SDH Kit ELISA, sord Kit ELISA, MGC83437 Kit ELISA, BmSDH Kit ELISA, PSPTO0363 Kit ELISA, SODH-1 Kit ELISA, RATSDHE1 Kit ELISA, SDH2 Kit ELISA, Sdh Kit ELISA, Sdhe1 Kit ELISA, TDH Kit ELISA, 4733401P19Rik Kit ELISA, AI836084 Kit ELISA, CGI-97 Kit ELISA, SDS Kit ELISA, zgc:63674 Kit ELISA, sorbitol dehydrogenase Kit ELISA, sorbitol dehydrogenase L homeolog Kit ELISA, Sorbitol dehydrogenase Kit ELISA, serine dehydratase Kit ELISA, SBDS ribosome maturation factor Kit ELISA, SORD Kit ELISA, Sord Kit ELISA, sord.L Kit ELISA, sord Kit ELISA, Sdh Kit ELISA, LOC733025 Kit ELISA, polS Kit ELISA, RS_RS10765 Kit ELISA, sdh Kit ELISA, smoS Kit ELISA, Rsph17029_1731 Kit ELISA, Srd Kit ELISA, RSKD131_1411 Kit ELISA, SDS Kit ELISA, Sds Kit ELISA, Sbds Kit ELISA
-