Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CEA Kit ELISA

CEA Reactivité: Humain Colorimetric Sandwich ELISA 0.2-250 ng/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN624958
  • Antigène Voir toutes CEA Kits ELISA
    CEA (Carcinoembryonic Antigen Gene Family (CEA))
    Reactivité
    • 4
    • 4
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.2-250 ng/mL
    Seuil minimal de détection
    0.2 ng/mL
    Application
    ELISA
    Fonction
    Human CEA ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Plasma, Cell Culture Supernatant, Serum
    Analytical Method
    Quantitative
    Specificité
    This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, ENA-78, FGF- 4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, I-309, IP-10, G-CSF, GM-CSF, IFN-gamma, Leptin (OB), MCP-1, MCP-2, MCP-3, MDC, MIP-1 alpha, MIP-1 beta, MIP-1 delta, PARC, PDGF, RANTES, SCF, TARC, TGF-beta, TIMP-1, TIMP-2, TNF-alpha, TNF-beta, TPO, VEGF.
    Sensibilité
    200 pg/mL
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling CEA Kit ELISA
    Top Product
    Discover our top product CEA Kit ELISA
  • Indications d'application
    Recommended Dilution for serum and plasma samples2 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use.
      2. Sample dilution: If your samples need to be diluted, Assay Diluent A (Item D) should be used for dilution of serum/plasma samples. 1x Assay Diluent B (Item E) should be used for dilution of culture supernantants and urine. Suggested dilution for normal serum/plasma: 2 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator.
      3. Assay Diluent B should be diluted 5-fold with deionized or distilled water before use.
      4. Preparation of standard: Briefly spin the vial of Item C and then add 640 µL Assay Diluent A (for serum/plasma samples) or 1x Assay Diluent B (for cell culture supernates/urine) into Item C vial to prepare a 250 ng/mL standard. Dissolve the powder thoroughly by a gentle mix. Pipette 400 µL Assay Diluent A or 1x Assay Diluent B into each tube. Use the 250 ng/mL standard solution to produce a dilution series . Mix each tube thoroughly before the next transfer. Assay Diluent A or 1x Assay Diluent B serves as the zero standard (0 ng/mL). 200 µL 200 µL 200 µL 200 µL 200 µL 200myl 640 µL + Item C vial 250 83.33 27.78 9.259 3.086 1.029 0.343 0 ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL ng/mL
      5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
      6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure.
      7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 1,000-fold with 1x Assay Diluent B. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 10 µL of HRP-Streptavidin concentrate into a tube with 10 ml 1x Assay Diluent B to prepare a final 1,000 fold diluted HRP- Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
      2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
      3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
      4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
      5. Discard the solution. Repeat the wash as in step
      6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
      7. Discard the solution. Repeat the wash as in step
      8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
      9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
    Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. Assay Diluent A Human CEA concentration (ng/mL) O D =4 50 n m 0.1 1 10 0.1 1 10 100 1000 Assay Diluent B Human CEA concentration (ng/mL) O D =4 50 n m 0.1 1 10 0.1 1 10 100 1000
    Sensitivity: The minimum detectable dose of CEA is typically less than 0.2 ng/mL.
    Recovery: Recovery was determined by spiking various levels of human CEA into human serum, plasma and cell culture media. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Serum 145.6 135-156 Plasma 103.8 82-124 Cell culture media 116.7 93-136
    Linearity: Sample Type Serum Plasma Cell Culture Media 1:2 Average % of Expected 96.28 99.63 106.6 Range ( %) 83-106 88-107 91-121 1:4 Average % of Expected 88.32 93.45 95.54 Range ( %) 75-104 81-106 85-107
    Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 %

    Précision du teste
    Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Yang, He, Liu, He, Yang, Du, Zhou, Wang, Zhang, Wu, Gao: "Down-regulation of CEACAM1 in breast cancer." dans: Acta biochimica et biophysica Sinica, Vol. 47, Issue 10, pp. 788-94, (2016) (PubMed).

  • Antigène Voir toutes CEA Kits ELISA
    CEA (Carcinoembryonic Antigen Gene Family (CEA))
    Autre désignation
    CEA (CEA Produits)
    Synonymes
    RGD1311281 Kit ELISA, carcinoembryonic antigen-related cell adhesion molecule 20 Kit ELISA, carcinoembryonic antigen gene family Kit ELISA, Ceacam20 Kit ELISA, Cea Kit ELISA
    Sujet
    The Human CEA (Carcinoembryonic Antigen) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human CEA in serum, plasma, cell culture supernatants and urine. This assay employs an antibody specific for human CEA coated on a 96-well plate. Standards and samples are pipetted into the wells and CEA present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human CEA antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of CEA bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.
    ID gène
    1048
    UniProt
    P06731
Vous êtes ici: