Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Insulin Kit ELISA

Ce kit ELISA Colorimetric est destiné à la mesure quantitative de Humain Insulin.
N° du produit ABIN8069781
1.004,26 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 25 à 47 jours ouvrables

Aperçu rapide pour Insulin Kit ELISA (ABIN8069781)

Antigène

Voir toutes Insulin (INS) Kits ELISA
Insulin (INS)

Épitope

S-acylated, total

Reactivité

  • 89
  • 26
  • 21
  • 13
  • 13
  • 13
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 2
  • 2
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Cell Lysate, Tissue Lysate
  • Fonction

    Measures s-acylated Insulin (INS) and total Insulin in human cell and tissue lysates, enabling precise assessment of Insulin s-acylation by ELISA. This assay can be developed for other species (mouse, rat, etc.) upon request. Contact techsupport@raybiotech.com.

    Analytical Method

    Quantitative

    Ingrédients

      Size / Qty
        • Microplate Coated With Anti-Pan-Insulin Antibody
        • Positive Control
        • HRP-Conjugated Streptavidin
        • 200 μL
        • Wash Buffer
        • Assay Diluent
        • Lysis Buffer
        • TMB One-Step Substrate Reagent
        • Stop Solution
        • S-Acylation Buffer A
        • S-Acylation Buffer B
        • S-Acylation Buffer C
        • S-Acylation Buffer D
        • S-Acylation Blocking Reagent
        • S-Acylation Reduction Reagent
        • S-Acylation Labeling Reagent

    Matériel non inclus

    • Acetone (pre-chilled (-20 °C))
    • Microplate reader capable of measuring absorbance at 450 nm
    • Protease and Phosphatase inhibitors
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Log-log graph paper or computer and software for ELISA data analysis
    • Absorbent paper
    • Tubes to prepare positive control or sample dilutions
    • Distilled or deionized water
    • Shaker
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and Positive Control as instructed.
    2. Block unmodified free cysteines using prepared S-Acylation Blocking Buffer at 50 °C with gentle rocking.
    3. Precipitate proteins with ice-cold acetone.
    4. Wash protein pellet twice with cold acetone/water mixture.
    5. Resuspend protein pellets in Buffers and adding Reducing and Labeling Reagents.
    6. Precipitate proteins with ice-cold acetone.
    7. Resuspend protein pellets.
    8. Add 100 μL sample and Positive Control to each well. Incubate 2.5 hours at room temperature or overnight at 4 °C with gentle shaking.
    9. Add 100 μL prepared HRP-Conjugated Streptavidin solution. Incubate for 1 hour at room temperature with gentle shaking.
    10. Add 100 μL TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
    11. Add 50 μL Stop Solution to each well. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Stock

    -20 °C

    Stockage commentaire

    The entire kit may be stored at -20°C for up to 6 months from the date of shipment. Avoid repeated freeze-thaw cycles.
  • Antigène Voir toutes Insulin (INS) Kits ELISA

    Insulin (INS)

    Autre désignation

    Insulin

    Sujet

    Gene Symbols: INS

    Background: The S-Acylated Insulin ELISA Kit uses a modified "biotin-switch" method to allow for the direct visualization of human S-Acylated Insulin by ELISA. In this S-Acylation biotin switch assay, unmodified free cysteines are first blocked. S-Acylated cysteines are then selectively reduced for specific labeling with biotin-maleimide reagents, which irreversibly bind to the cysteine thiol that was S-Acylated. Biotinylation of the newly formed thiol groups can then be detected by ELISA. An anti-pan Insulin antibody has been coated onto a 96-well plate. Biotinylated samples are pipetted into the wells, and Insulin present in a sample is bound to the wells by the immobilized antibody. The wells are washed, and HRP-conjugated streptavidin is used to detect S-Acylated Insulin. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of S-Acylated Insulin bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

    Protein Name (Synonyms): Insulin

    ID gène

    3630

    UniProt

    P01308

    Pathways

    Signalisation NF-kappaB, Signalisation RTK, Positive Regulation of Peptide Hormone Secretion, Peptide Hormone Metabolism, Hormone Activity, Carbohydrate Homeostasis, ER-Nucleus Signaling, Regulation of Carbohydrate Metabolic Process, Feeding Behaviour, Autophagy, Negative Regulation of intrinsic apoptotic Signaling, Brown Fat Cell Differentiation, Positive Regulation of fat Cell Differentiation
Vous êtes ici:
Chat with us!