Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

TNFRSF13C Kit ELISA

TNFRSF13C Reactivité: Humain Colorimetric Sandwich ELISA 0.156-10 ng/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN454493
  • Antigène Voir toutes TNFRSF13C Kits ELISA
    TNFRSF13C (Tumor Necrosis Factor Receptor Superfamily, Member 13C (TNFRSF13C))
    Reactivité
    • 6
    • 6
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.156-10 ng/mL
    Seuil minimal de détection
    0.156 ng/mL
    Application
    ELISA
    Fonction
    This immunoassay kit allows for the specific measurement of human B cell activation factorr from the tumor necrosis factor family receptor, BAFF-R concentrations in cell culture supernates, serum and plasma.
    Type d'échantillon
    Cell Culture Supernatant, Serum, Plasma
    Analytical Method
    Quantitative
    Specificité
    This assay recognizes recombinant and natural human BAFF-R.
    Réactivité croisée (Details)
    No significant cross-reactivity or interference was observed.
    Sensibilité
    < 39 pg/mL
    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest detectable concentration that could be differentiated from zero.
    Attributs du produit
    Homo sapiens,Human,Tumor necrosis factor receptor superfamily member 13C,B-cell-activating factor receptor,BAFF receptor,BAFF-R,BLyS receptor 3,TNFRSF13C,BAFFR,BR3,CD268
    Ingrédients
    Reagent (Quantity): Assay plate (1), Standard (2), Sample Diluent (1x20ml), Assay Diluent A (1x10ml), Assay Diluent B (1x10ml), Detection Reagent A (1x120µl), Detection Reagent B (1x120µl), 2 Wash Buffer(25 x concentrate) (1x30ml), Substrate (1x10ml), Stop Solution (1x10ml)
    Featured
    Discover our best selling TNFRSF13C Kit ELISA
    Top Product
    Discover our top product TNFRSF13C Kit ELISA
  • Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    This assay employs the quantitative sandwich enzyme immunoassay technique. A antibody specific for BAFF-R has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any BAFF-R present is bound by the immobilized antibody. An enzyme-linked antibody specific for BAFF-R is added to the wells. Following a wash to remove any unbound antibody-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of BAFF-R bound in the initial step. The color development is stopped and the intensity of the color is measured.
    Préparation des réactifs

    Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer. Standard - Reconstitute the Standard with 1.0 mL of Sample Diluent. This reconstitution produces a stock solution of 20,000 pg/mL. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The diluted standard serves as the high standard (10,000 pg/mL). The Sample Diluent serves as the zero standard (0 pg/mL). Detection Reagent A and B - Dilute to the working concentration specified on the vial label using Assay Diluent A and B (1:100), respectively.

    Prélèvement de l'échantillon
    Cell culture supernates - Remove particulates by centrifugation and assay immediately or aliquot and store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1000 x g. Remove serum and assay immediately or aliquot and store samples at -20 °C. Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 x g at 2 - 8 °C within 30 minutes of collection. Store samples at ≤ -20 °C. Avoid repeated freeze-thaw cycles. Note: Citrate plasma has not been validated for use in this assay.
    Procédure de l'essai

    Allow all reagents to reach room temperature. Arrange and label required number of strips. 3
    1. Prepare all reagents, working standards and samples as directed in the previous sections.
    2. Add 100 uL of Standard, Control, or sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37 °C.
    3. Remove the liquid of each well, don’t wash.
    4. Add 100 uL of Detection Reagent A to each well. Incubate for 1 hour at 37°C. Detection Reagent A may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
    5. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (350 uL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    6. Add 100 uL of Detection Reagent B to each well. Cover with a new adhesive strip.Incubate for 1 hours at 37 °C.
    7. Repeat the aspiration/wash as in step
    5. 8. Add 90 uL of Substrate Solution to each well. Incubate for 30 minutes at room temperature. Protect from light.
    9. Add 50 uL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
    10. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
    Important Note:
    1. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings.
    2. It is recommended that no more than 32 wells be used for each assay run if manual pipetting is used since pipetting of all standards, specimens and controls should be completed within 5 minutes. A full plate of 96 wells may be used if automated pipetting is available.
    3. Duplication of all standards and specimens, although not required, is recommended. 4
    4. When mixing or reconstituting protein solutions, always avoid foaming.
    5. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
    6. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.

    Calcul des résultats

    Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the BAFF-R concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    1. The kit should not be used beyond the expiration date on the kit label.
    2. Do not mix or substitute reagents with those from other lots or sources.
    3. If samples generate values higher than the highest standard, further dilute the samples with the Assay Diluent and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
    4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.
  • Antigène Voir toutes TNFRSF13C Kits ELISA
    TNFRSF13C (Tumor Necrosis Factor Receptor Superfamily, Member 13C (TNFRSF13C))
    Autre désignation
    TNFRSF13C (TNFRSF13C Produits)
    Synonymes
    RGD1560810 Kit ELISA, TNFRSF13C Kit ELISA, BAFF-R Kit ELISA, BAFFR Kit ELISA, BROMIX Kit ELISA, CD268 Kit ELISA, CVID4 Kit ELISA, prolixin Kit ELISA, 2010006P15Rik Kit ELISA, Baffr Kit ELISA, Bcmd Kit ELISA, Bcmd-1 Kit ELISA, Bcmd1 Kit ELISA, Lvis22 Kit ELISA, TNF receptor superfamily member 13C Kit ELISA, uncharacterized LOC746611 Kit ELISA, tumor necrosis factor receptor superfamily, member 13c Kit ELISA, TNFRSF13C Kit ELISA, Tnfrsf13c Kit ELISA, LOC746611 Kit ELISA
    Sujet
    BAFF receptor (BAFF-R/BR3/TNFRSF13C) is a recently identified molecule that specifically binds BLyS, a protein belonging to the tumor necrosis factor (TNF) family, and is involved in survival and maturation of B cells. Recent studies have demonstrated that mice defective in BAFF-R gene exhibit an altered profile of the B cell pool, a phenotype observed in BLyS knockout mice as well. These features suggest that mutations in this gene may result in humoral immunodeficiency.
    Pathways
    Signalisation NF-kappaB
Vous êtes ici:
Support technique